40-7705I-UM Page 80 Rev 4 March 16, 2007
Function Explanation
ZONE CONFIGURATION
• Press <ALT> + <P>
• Press <Z>
• Select Target Unit
• Select Route
• Edit form as necessary
See below for details on data entry for this function:
This function configures alarm zone inputs for a premise unit. It is
important to know which type of unit is being programmed. There are
separate sub-menus to handle the different subscriber units. The sub-
menu that will be presented upon selection of a subscriber ID is based on
the database entries. The subscriber model may be selected during setup
in the Admin GUI and using the Get All function in the message group
will update all fields required to identify the unit.
Subscriber models include:
7050/7750-UL (Version 1.8 or older) 7750
7050-E (Version 1.8 or older) 7750F 4X4
7050-E / F8 (Version 2.0 and newer)
To access the Programming function menu group, hold down the <Alt>
key and Press <P>. The Programming window illustrated below will
appear. Select zone Configuration then [OK]. Proceed by selecting your
target unit and choosing a route of communication.
Sample Zone Configuration windows for the various Subscribers are
shown below.
Fire/Inverted Fire programming notes:
If the Subscriber type selected supports Fire and Inverted Fire
programming, these notes apply to the programming sequence and the
following questions will appear before the zone programming selection
window.
Figure 11-16
The programming sequence first asks if any zones are to be programmed
to respond similar to a "Fire circuit". This is not to be confused with the
device usage, but rather how changes to the EOL will be reported. Click
yes if you wish to have the zone report "Trouble" conditions on an open
circuit and alarm on a short. Otherwise click No for alarm message to be
reported on a short or open. A raised appearing button indicates the
default or current programming, if it is stored in the database from a