5.12 Review your TCP/IP Configuration:
The TCP/IP parameters of all TCP/IP devices must be properly configured in
order for the MultiNet Receiver to communicate with any local or remote IP-Link
Transceiver(s), and any other TCP/IP devices it needs to communicate with.
As stated before, if you are connected as shown in Figure 4-1 using the 7170 that
was shipped with your receiver, then no configuration is needed for the pair to be
operational.
There are two Ethernet adapters incorporated into the MultiNet Receiver. One is
identified as eth0 the other as eth1. You can issue the Linux command ifconfig
at a command prompt to review the TCP/IP settings. It is best to request IP
information one adapter at a time. Enter the following to view Port 1 settings:
ifconfig eth0<Enter>
Review the data on the screen. Then, to review the settings of Port 2, the second
adapter, enter the following:
ifconfig eth1<Enter>
You can scroll the screen display to view information that has scrolled off by
using the <Pg Up> and <Pg Dn> keys.
5.13 Factory Default TCP/IP Settings
The table below shows the factory default settings of all TCP/IP devices in a
MultiNet Receiver / 7170 IP-Link transceiver pair. Both Receivers and IP-Link
Transceivers in a dual system are configured the same from the factory. You
MUST modify the TCP/IP settings of the second Receiver and IP-Link
Transceiver before the two can be connected together in the same network. If the
new MultiNet system is being placed in a network that has existing MultiNet
devices then these new devices need unique settings.
Failure to do so will result in conflicts.
7705i Default Ethernet Port Settings
Parameter Ethernet Port 1 / eth0 Ethernet Port 2 / eth1
ONBOOT Yes Yes
BOOTPROTO STATIC STATIC
IPADDR 192.168.0.101 10.0.1.221
NETMASK 255.255.255.0 255.255.255.0
GATEWAY 192.168.0.1 10.0.1.7
7170 IP-Link Transceiver Default Ethernet Port Settings
IP Address 192.168.0.11
GATEWAY 192.168.0.1
NETMASK 255.255.255.0
Table 5-4 Factory default TCP/IP settings