40-7705I-UM Page 110 Rev 4 March 16, 2007
All other Contact ID Event Codes will be reported as:
Y XXX where XXX is a copy of the event code. OR
SY XXX when PXXX is the event and where XXX is the Point ID or Contact ID number
Note: AES recommends not using Radionics 6500 emulation, when using IntelliTap to report Contact ID. If at all possible use
Ademco 685 emulation if you have a monitoring system that can support it.
( Line card #4 next page)
Line Card # 4 4+2 received from IntelliTap. Events are translated.
Signal format: 1RRLssssssACCTsAssCC<0x14>
A = Character A for alarm event.
CC = two digit zone code.
See “Line card #1”, “Signal format” in “Mode 1 – Radionics 6500 compatible output” for explanation of other signal
format codes.
Event plus Zone, Status and Fault Codes, AES Subscribers with IntelliTap.
All 4+2 messages will be reported as follows:
AssCC where CC is a direct copy of the received 4+2 report code.
Input Signals:
In mode 1 the AES receiver will respond to two inputs or signals from the monitoring system.
<0x06> receiver considers last message acknowledged
<0x15> receiver will re-send last message (if not acknowledged)
Other Messages:
301ssAESs7000sVX.XXs<0x14>
X.XX this reports the version number of the firmware
Komentáře k této Příručce